Gas column repair by own hands

Any professional will tell you: "The gas column is a potentially dangerous equipment, so you can trust the service and repair only to a qualified specialist."However, the ability to understand which element has failed and what it can lead to, definitely will not hurt.

Gas column repair by own hands

Repairing the gas column with your own hands

In addition, with the elimination of some faults that do not specifically affect the gas equipment can be handled on their own. Read the description of typical breakdowns and recommendations for action in case of their detection.

The device of a gas column

Gas column device

Gas column refuses to ignite

Content of the article

  • 1 Gas column refuses to ignite
  • 2 Gas column dries
  • 3 Water comes out with a weak pressure
  • 4 The column "claps"
  • 5 The column does not heat up the water
  • 6 When the heater starts to smell like gas
    • 6.1 Video Repairgas column with their own hands

The equipment may stop lighting for several reasons.

The device of a gas column

Gas column device

First of all you should make sure that the ignitor is working properly. If it does not burn, please contact the gas department. The specialist will clean or replace the failed component. You can not touch it yourself - it's dangerous.

The scheme of the device of a gas column

Diagram of gas column device

In modern units with electronic ignition in the absence of ignition, the gas ceases to be supplied - it is cut off by the valve. The user will learn about this by means of an appropriate indicator. In some situations, this problem is solved by simply replacing the battery. This point, please check the instructions. If the manufacturer does not give such recommendations, it is better to immediately apply to the gas service or third-party repair service.

At one point the column may not be lit

At some point the column may not light up

Battery pack for ignition of the column

Battery pack for ignition of

column The column will not light if there is no ventilation draft. To check the level of traction, we bring a strip of paper to the ventilation grate. If the leaf does not change its position or changes it is not sufficiently expressed, with the traction obvious problems. In apartment buildings, cleaning of the ventilation wells is carried out by the communal services - contact them. You can do this yourself using a metal brush attached to a suitable flexible wire( hose, etc.), however utilities do not usually approve of such unauthorized actions.

Cleaning of ventilation

Cleaning the ventilation

Often, the burners do not work due to the wear of the membrane. This element of construction is quickly deformed, the trigger mechanism of the burner becomes less sensitive and does not work when the water is turned on. Even in expensive heaters, membranes wear out for 5-8 years - with this, unfortunately, nothing can be done about it.

Often the burners do not work due to the wear of the membrane

Often, the burners do not work because of the deterioration of the

membrane. To check, turn on the water to maximum. If the column is turned on with a strong head, the problem is definitely in the membrane. You can replace this element with your own forces.

To do this, proceed as follows:

  • , unscrew the nuts from the water assembly( usually 2);
  • unscrew the fixing screws, due to which the water unit is held in the gas( usually screws 3);
  • disconnect the halves of the assembly and you will see a rubber membrane. If it is not flat, but noticeably deformed, replace it. To do this, buy a similar product in a specialized store. If possible, give preference to a silicone membrane - it will last much longer than its simple rubber counterpart.

At the same stage you can check the status of the filter of the receiving device. If it is clogged, clean it or replace it with a new one. For cleaning simply unscrew the nut from the water supply side, remove the mesh and wash it or replace it with a new one, depending on the condition.

The gas column will dry

The gas column will go out

The gas column will dry up

If the heater turns on but goes dead, the problem in most situations is the bimetallic temperature sensor necessary to protect the equipment from overheating. Also, due to malfunctioning of this element, the heater may not turn on at all.

This problem has two main development scenarios.

  1. According to the first scenario, the burner lights up properly, the equipment functions for some time without any complaints, and then it dries and for some time does not show any signs of life - attempts to ignite the heater lead to nothing. Usually after 20-30 minutes the equipment turns on again and the history repeats itself. This is due to the excessive sensitivity of the sensor. As a rule, it is "congenital", i.e.this factory marriage. It is extremely difficult to do something independently. It is better to immediately contact the manufacturer's service for warranty repair.
  2. In accordance with the second scenario, the column can be switched off randomly, and sometimes not included at all. The reason, as a rule, consists in deterioration of an insulating material of a conductor of the bimetallic gauge. There is a banal closure on the body, as a result of which the safety valve is triggered, and the column begins to behave abnormally.
    Contact a service center for warranty repair

    Contact the service center for warranty repair.

. It is pointless to apply to the gasmakers - the defect is clearly not "gas".Trying to get rid of the breakdown yourself is also not necessary - you can only break the unit. Contact the service center for warranty repair.

Water comes out with a weak pressure

Water comes out with a weak pressure

Water comes out with a weak pressure

Most often this happens due to clogging of the column heat exchanger with scum. Usually, the cause of blockage is the continuous "idle" operation of the ignitor. The device heats the heat exchanger to a temperature sufficient to cause evaporation of moisture residues.

There is no water flow, the scale is not washed out from the heat exchanger, it clings until the next switching on of the equipment, as a result of which the column ceases to function normally. Usually it saves the cleaning of the heat exchanger. In neglected cases, it has to be changed.

For replacement it is better to contact professionals at once, but with cleaning you can do it yourself. Prepare a screwdriver, rubber hose, car keys and paranitic gaskets. Buy a mixture at the hardware store to remove scale. Usually it is called antikonakin. More budgetary option - washing with vinegar essence. Work in this order.

The first step. Consistently remove the hardware and cover from the heater.

The second step. Close the water at the inlet and open the hot water tap, preferably as far from the column as possible.

The third step. Unscrew the water supply pipe from the heat exchanger, and then pull it aside. After unscrewing the nut, the column heat exchanger will begin to pump water. In total it will be about 1 liter.

Fourth step. Fit a suitable diameter hose to the heat exchanger inlet and lift it slightly above the heater. Insert into the fixed hose an ordinary funnel and start slowly, with a thin stream, pour in the ready-made solution( the preparation instruction is given on the package).Do not hurry. You will pour too quickly - the anti-kipin will simply push you back, and you are unlikely to like it.

Flushing the gas column heat exchanger

Flushing the gas exchanger of the gas column

Leave the cleaning agent in the heater's heat exchanger for 2-3 hours( usually the required time is indicated on the package).

Place a suitable container under the water tap and gently renew the fluid supply to the heater. Observe what comes out of the hose. There was a lot of sludge, and then the pressure became normal? All is well. In the opposite situation, the washing will have to be repeated. Usually the need for rewashing occurs only when using acetic essence. Antinakipin in most situations copes with the first time.

Column "claps"

The column "claps"

Column "claps"

In such a situation it is better to immediately contact a professional. He will perform the adjustment, which it is extremely difficult to produce without knowledge of the case, and the column will start working normally.

You can also find out the reasons for such a malfunction for general development. The main reasons are two:

  • gas comes under too much pressure. The heater lights up too actively, which leads to a fire failure;
  • gas comes under too low a head. The air heater penetrates the burner of the heater, which leads to a microexplosion, which is regarded by the human hearing as cotton.

The column does not heat up the water

The column does not heat the water sufficiently

The column does not heat up the water

This is usually due to the insufficiently high power of the gas column. The user starts to demand from the equipment more than it can do.

There are two options for solving the problem:

  • is no longer abused and does not open hot cocks at all points of water intake at the same time;
  • buy a more powerful column.

Also, inadequate liquid heating may occur due to clogging of the burner. Look at the color of the fire. Under normal conditions, it is bluish. If the flame turns yellow, please contact the gas vendors. Trust such repairs can be exclusively professional, tk.this is a "gas" breakdown.

When the heater is turned on it starts to smell like gas

The column smells of gas

Column smells like gas

The problem is more than serious. Do not think about any self-repair. Turn off the heater, close the gas cock, ensure sufficient ventilation of the housing and immediately call the gas service. The brigade arriving at the scene will evaluate the problem and take appropriate measures.

Now you know the main faults of the gas column, and you know how to behave when they appear. The main thing - remember about safety. Do not try to fix the breakdown, for the elimination of which you do not have enough qualifications - this can lead to irreparable consequences.