Wiring diagrams of water warm floors in a private house

click fraud protection

The process of mounting the water underfloor

The process of mounting the water underfloor

warm water floor mount technology

Mounting technology warm water floors distinguished on the basis of the heating circuit the base of the device. The basis for warm water floors is selected considering load capacity ceiling and the intended floor covering. View video wiring diagrams warm water floors in a private house will have a clear idea of ​​the sequence of operations and work performance technology.

Experts call warm water floating floors. Damper band width of 12 ÷ 18 cm is mounted on the perimeter of the room, and each circuit, when the room is divided into the independent sector. The edge adjustment film screed temperature plays a role seam. Absorber provides safety flooring and heating circuit with thermal expansion, vibration, and shifting of building structures. Tape reduces heat losses in the heating field plate joints with outer walls.

Driving underfloor heating installation for the rooms on the first floor of a private house

Driving underfloor heating installation for the rooms on the first floor of a private house

Concrete slabs arrange a warm water floor filler in the cement screed. Concrete foundation waterproofing lining is laid a layer of insulation and a mesh. Pipes to the carcass cells attached by clamps, fasteners or special steel wire. Atop the tubular contour for uniform distribution of service load floor covering, reinforced coupler is also satisfied, if necessary.

Lightweight foundation that combines the functions of a heater and a frame - folding or special profiled mats made of extruded polystyrene. In the former case a tube is fixed on the substrate surface with special clamps harpoon lugs or mounting rails. On profiled mats circuit loop tightly fixed boss, additional fasteners are not required. An improved version of profiled mats are coated with a waterproofing system and equipped with locking projections.

Scheme water laying of floor heating in the "dry" areas of the second floor

Scheme water laying of floor heating in the "dry" areas of the second floor

Important! Installation of polystyrene system requires accuracy. Team under the screed flooring performed immediately after pipe laying. Surface elements made of foamed plastic material withstands distributed loads but readily prominaetsya fallen under the heel or tool.

Modular furniture made of wood or wood composite placed on a rough floor. Wooden rack-type system formed by the joists. Rotary and straight grooves grazing systems made of wood used for packing heat-distribution plates made of galvanized steel or aluminum.

The pipes that are used for displaying the warm floor water (crosslinked polyethylene, metal and copper, Stainless steel flexible corrugated with an inner polymer coating, rarely polypropylene) for producing the seamless technologies. Circuit spread from a single tube. Butt connection with the standard fittings in the body of the screed is permissible only for the contours of the corrugated pipe. The surface of the pipe should be resistant to oxygen corrosion, thermal margin and mechanical strength, have a smooth inner surface.

Installation diagram water floor heating in the "wet" rooms second floor

Installation diagram water underfloor in "wet" rooms second floor

Bay pipes for floor heating beforehand not dismiss - careless handling can lead to the formation of creases. Installation start of the feed comb collector. Gradually unwound bay operate scheduled layout, and returned to the distributor pipe whole. Circuit combined with paired nozzles combs collector.

After installation of the system of floor heating circuit is checked for strength and tightness. After a successful test, and the test run is poured cement screed. Finish flooring mounted after drying screed.

Wiring diagrams floor warm water to the heat source

Independent heat generator in a private home heats the water to 95 ° C. Optimum temperature difference between flow and return - 20 ° C. However, the maximum allowable temperature coolant system underfloor - 55 ° C, heat removal is 5 ° C. In practice, a floor primary coolant does not exceed the operating range 40 ÷ 35 ° C.

Heating Scheme house with automatic temperature control smokers: 1A - 16 mm tube; 1B - 26 mm tube; 2 - valve ball; 3 - continuous-flow valve; 4 - 24 l tank membrane; 5 - circulation pump; 6 - check valve; 7 - a group of security; 8 - the collecting unit; 9 - electrothermal actuator; 10 - electronic thermostat; 11 - the switch cabinet; 12 - connector; 13 - self-sealing plug; 14 - pin; 15 - crimp connector; 16 - bellow; 17 - valve ball

Heating Scheme house with automatic temperature control smokers: 1A - 16 mm tube; 1B - 26 mm tube; 2 - valve ball; 3 - continuous-flow valve; 4 - 24 l tank membrane; 5 - circulation pump; 6 — check valve; 7 - a group of security; 8 - the collecting unit; 9 - electrothermal actuator; 10 - electronic thermostat; 11 - the switch cabinet; 12 - connector; 13 - self-sealing plug; 14 - pin; 15 - crimp connector; 16 - bellow; 17 - valve ball

The temperature was controlled by a forced mix with streams: part of the return heat transfer medium flows into the supply conduit. Mixing units installed between the boiler and distribution manifold.

There are models of gas appliances that are built-in floor heating circuit: Automatic operation in "warm floors" mode restricts the flow temperature at the outlet from the boiler to 45 ° C. Operation of the conventional gas boiler in floor heating mode reduces the efficiency of operation of the unit.

Long burning solid fuel in wood burning distinguishes complicated adjustment mode. The apparatus of underfloor heating systems with a heat generator for solid fuels, in addition to the circulation pump, the installation requires buffering capacity. The coolant in the floor heating system is taken directly from the pressure accumulator.

Wiring diagram of warm water floors for solid fuel boiler

Wiring diagram of warm water to the floor solid fuel boiler

Electric boilers - the most convenient and viable option for efficient operation underfloor. Automation electrode, induction or aggregates with a tubular electric heater capable of maintaining a predetermined coolant temperature without losing thermal power boiler. Floor heating houses a small area (up to 100m2) allows direct connection to the circuits of electric boilers. Underfloor heating private houses a large area using coplanar arrange Manifold and mixing unit.

Related article:

vodyanoj-teplyj-pol-svoimi-rukami-1mWater warm floor with their hands, video and description of the process. Mounting nuances. Description of the installation process of the water floor heating. Its strengths and weaknesses as opposed to other species.

Wiring diagrams warm water floors in apartment

Primary or secondary low-temperature circuit of underfloor central heating systems in apartment houses plan the development of the project. To make changes in the radiator heating circuit apartment house prohibited housing law. The temperature of the radiator circuit above required parameters for underfloor. Unauthorized change of direction, diameter and length of heating obschedomovogo riser leads to unbalance the system and disturbance of the thermal regime in a building.

Specialized organizations to make installation of underfloor heating from the central heating in apartments during the construction of the building. The principle of the device of underfloor central heating in the flat connection method distinguishes the low-temperature circuit. The coolant enters the water underfloor pipe separately from the radiator heating, standpipe. Hot water for floor heating preparing a heat exchanger, which is installed in the central heating, thermal node apartment building, or directly in the flat consumer.

Scheme tapping of warm water sexes radiator central heating circuit 1 - the ball valve in the inset feed line; 2 - ball valve to reverse the inset; 3 - strainer; 4 - check valve; 5 - a three-way mixing valve; 6 - the bypass valve; 7 - circulation pump; 8 - the valve on the return manifold outlet; 9 - shut-off valve at the feed inlet manifold; 10 - a return manifold; 11 - the case of the supply reservoir; 12 - Ball valves on return pipe loop; 13 - Ball valves on the supply circuit; 14 - vent valve; 15 - drain valve; 16 - radiator

Scheme tapping of warm water sexes radiator central heating circuit 1 - the ball valve in the inset feed line; 2 - ball valve to reverse the inset; 3 - strainer; 4 - check valve; 5 - a three-way mixing valve; 6 - the bypass valve; 7 - circulation pump; 8 - the valve on the return manifold outlet; 9 - shut-off valve at the feed inlet manifold; 10 - a return manifold; 11 - the case of the supply reservoir; 12 - Ball valves on return pipe loop; 13 - Ball valves on the supply circuit; 14 - vent valve; 15 - drain valve; 16 - radiator

Theoretically, change the length of tube without compromising the thermal regime in adjacent flats may last (in the direction of coolant movement in the riser) consumers. If the heat is distributed from above, the floor heating on the ground floor does not affect the heat apartments located above. However, the operating pressure supply pipe at the bottom postoyachnoy wiring may not be sufficient to circulate the outdoor upper deck contour.

In the absence of initial design data for floor heating device in an apartment house additional circuit connectivity check with the supplier of thermal energy and control company. Resursosnabzhayuschie organizations authorize the device is warm semi-floors, with sufficient reserve capacity of the existing heating system.

Combined heating in the flat using water radiators and floor heating

Combined heating in the flat using water radiators and floor heating

Housing maintenance companies impose a mandatory condition for the estimated load the bases warm floors, which should not exceed the allowable load on the floor structures, in this particular case.

Traditionally, the coordination involves the installation of a heat exchanger on the radiator or hot water riser in the apartment. This requires the installation of the circulation pump, an expansion tank, a security group, a valve for removal of air, the two-way cock, and control valves heat meter.

Semiautonomous warm water circuit connecting floors in apartment 1 - ball valve inset into the feed riser; 2 - ball valve to bypass the return risers; 3 - strainer; 4 - check valve; 5 - a two-way valve (servo sensor); 6 - the bypass valve; 7 - circulation pump; 8 - the valve on the return manifold outlet; 9 - shut-off valve at the feed inlet manifold; 10 - a return manifold; 11 - the case of the supply reservoir; 12 - Ball valves on return pipe loop; 13 - Ball valves on the supply circuit; 14 - vent valve; 15 - drain valve; 16 - heat exchanger; 17 - a group of security; 18 - thermometer; 19 - control valves; 20 - bypass between the supply and return manifold; 21 - expansion membrane

Semiautonomous warm water circuit connecting floors in apartment 1 - ball valve inset into the feed riser; 2 - ball valve to bypass the return risers; 3 - strainer; 4 - check valve; 5 - a two-way valve (servo sensor); 6 - the bypass valve; 7 - circulation pump; 8 - the valve on the return manifold outlet; 9 - shut-off valve at the feed inlet manifold; 10 - a return manifold; 11 - the case of the supply reservoir; 12 - Ball valves on return pipe loop; 13 - Ball valves on the supply circuit; 14 - vent valve; 15 - drain valve; 16 - heat exchanger; 17 - a group of security; 18 - thermometer; 19 - control valves; 20 - bypass between the supply and return manifold; 21 - expansion membrane

For several floor circuits using ready manifold assembly that is compatible with any scheme of laying the floor. Each input and output with the comb manifold shut-off valve or the thermostat to be set. Shut-off valve makes it possible to disconnect individual circuit without breaking the overall operation of the underfloor heating.

Particular attention is paid to the choice of the base of warm floors in the homes of old buildings. The transverse dimension of screed depends on the degree of insulation slabs. "Pie" Thickness warm floors above the cold cellar reaches 0.15 m, which substantially conceals the overall height of the room and increases the weight of the structure.

The process of roughing screed underfloor heating under tiles or other covering with your hands

Process roughing screed underfloor heating under tiles or coating with your hands

Useful advice! A reasonable solution would be to opt for the lightweight bases to the water with underfloor heat exchanger plates of stainless steel or aluminum.

The cost of installation of warm water floor

The total price of the installation of warm water floor includes money spent on the purchase of materials, execution calculations, preparation works, laying, wiring and hydraulic test of strength and density of circuits compounds.

Professionals hired services will cost 1,500 ÷ 2,500 rubles per 1 m² of floor heating. Total amount depends on the number of circuits, the type of substrate, the cost of the pipes, the collecting groups and pump-mixing unit. It allows you to reduce the cost of installation of warm water floor with their hands.

Mounting of the heating system "warm floors": 1 - a pipe XLPE 2 - insulating mats, 3 - Pipe fastening bracket 4 - Feed damper, 5 - collector 6 - collector cabinet 7 - wall thermostat 8 - softener

Mounting of the heating system "warm floors": 1 - a pipe XLPE 2 - insulating mats, 3 - Pipe fastening bracket 4 - Feed damper, 5 - collector 6 - collector cabinet 7 - wall thermostat 8 - softener

Important! The quality of the material, equipment, valves and control valves must comply with the appointment system and terms of its intended life. Advantageously acquire complete sets of warm floors, which are equipped with high quality and consistent in equipment and materials. Free calculation of warm water floors for batch purchase - an added bonus from major manufacturers.

Posted on the Internet a video installation of water warm floor with their hands, with explanations of the authors, will help to better understand the issue. Detailed descriptions of the methods of arrangement and selection of material for underfloor heating help in the event that there is an urgent need for underfloor heating, but there is no opportunity for the hiring of specialists.

instagram viewer